Miller® SAR BreatheAir™ Panel Filtration System - 4 Person 275970
The Miller® SAR BreatheAir™ Panel Filtration System produces Grade D breathing air (CO < 10ppm) at 125 CFM for up to 4 persons using Supplied Air Respirators. Three-stage filtration system removes 99.99% of fine oils and mists, and particulates down to .01 microns. It also removes organic vapors, odors and tastes. Built-in external warning lights and audible alarms clearly indicate when the supplied air's carbon monoxide levels exceed 10 parts per million. Each of the three individual filter cartridges have change indicators that clearly notify the user when the cartridge has reached the end of its usable life.
The BreatheAir 4 Person Panel filtration system is a stationary, wall-mounted system and weighs 45 pounds. When teamed with the Miller Supplied Air Respirator with C50 regulator (SOLD SEPARATELY), the operator can enjoy Grade D breathing air under the hood at temperatures up to 50 degrees F cooler than the surrounding environment.
The system comes complete with three-stage filters, regulator, quadruple manifold with female 1/2 inch industrial interchange quick disconnect fittings and built-in CO monitor with visual and audible alarms.
Process
Loose Fitting Supplied Air Respirator (SAR) Filtration System
Applications
Manufacturing
Fabrication
Stainless Steel
Flux Cored
Features
Three-stage filtration process provides
respiratory users Grade-D breathing air while
monitoring for CO during use, ensuring
compliance and worker safety.
First stage removes 95 percent of liquids and
particulate down to 5.0 microns.
Second stage removes 99.99 percent of fine oil mists and particulate down to .01 microns
in size.
Third stage removes organic vapors, odors
and tastes.
Filter change indicators clearly notify users of
needed change, eliminating guesswork and
amplifying unit performance.
Filter change process is quick and
easy, minimizing downtime.
Automatic condensation drain extends filter life.
Internal monitor continuously monitors carbon
monoxide (CO) levels in the breathing air.
External warning lights and alarms quickly
notify users of heightened CO levels, reducing
user reaction time.
Calibration of CO monitors takes less than
two minutes, reducing operator downtime while
increasing safety.
Durable construction designed to perform in
the toughest industrial applications.
4 Person system can be used by one or up to four operators
Recommended for use with the Miller SAR (Supplied Air Respirator) with C50 regulator system.
BreathAir™ Specs
Minimum air compressor size - 75 PSIG at 60 CFM (cubic feet per minute) for 4 person box/panel.
Maximum air compressor inlet pressure - 125 PSIG (BreatheAir systems have a 125 PSIG internal safety that will release at inlet pressures above 125 PSIG).
NOT INTENDED FOR USE IN IDLH ENVIRONMENTS (Immediately Dangerous to Life or Health Environments)
Comes complete with
BreatheAir™ 4 Person Panel with 1/2 inch industrial interchange inlet
Three-stage air filtration system with filter cartridges
Carbon Monoxide monitor with visual and audible alarms